_______ ( ____ \ | ( \/ | | | | ____ | | \_ ) | (___) | (_______)
_ | | _ | | | |_| | \___/
______ ( __ \ | ( \ ) | | ) | | | | | | | ) | | (__/ ) (______/
##### ## #### ## #####
_______ |__ __| | | | | | | |_|
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: I have Genboard 3.3 (1.0.53) installed on my car, and i have some problems with those .bat files installed on my computer. When connected to car, download-config.bat works fine, but when running generate-config.bat it doesn´t work right. Tables.mtt is generated ok, but config.mtt have ERROR text first on every line. At the end it says Config.mtt generated with 255 errors and 0 warnings.??? *check your downloaded config.txt in /config that it is correct *check your /firmware that is has correct global.h in it *if previous doesn't give any results, download new VemsMT release and replace old makeconfig.exe with the one from new package Tried with new .exe file , but still the same... at what com-port is your laptop communicating with genboard? when this is another com-port as the bat-file uses then you have to edit the batfile with a texteditor to adjust its com-port. Tim Edit your config.txt with Programmers notepad, Do not use windows notepad. There is note about this in here somewhere on wiki. I had similar problems because windows notepad somehow mixed up config.txt and give multiple errors when trying to generate config. Then finally editing with Programmers notepad there was many lines containig text from multiple lines. I separated texts to their own lines, saved and everything worked OK! 25.03.07 Doesn´t work either.... I´ve got false reading in clt and mat at lower temperatures, when temp is like +15c outside,lcd shows then +22 or +23 celsius. I´ve measured those sensors, and there´s my list: MAT 1 6140 10 4080 20 2720 30 1840 40 1279 46,5 1000 50 882 60 630 70 459 80 343 90 263 CLT - 1 5770 10 3960 20 2630 30 1760 40 1208 50 856 60 607 70 449 80 331 90 270 I´ve read that easytherm thing but imo it´s bit messy.. So could somebody tell me what to do to get those readings right? Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.