_ _ | \ | | | \| | | |\ | |_| \_|
_ __ | |/ / | ' / | < | . \ |_|\_\
# ### ## # # # # # # #
_____ / ____| | | __ | | |_ | | |__| | \_____|
##### ## #### ## #####
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Just a place to jot down varius issues i ran into, hope they help the next person! Some injectors not opening: * First array element in h[0] not opening * manually triggering the array output using mdh command. All other array elements worked regardless of output. this is discussed briefly on the bottom of this page GenBoard/Manual/DigitalOut From what i found, alot of the misc outputs were set to injgroups that fire injector channels through h[0] entries. I opened up the Megatune and opened the tab for all outputs table. Most of them i wasn't using, and i just set them to disabled. This cleared up the issue - but boy was it a pain to figure out. ------------------------- Error in vemsv3.ini Found this in both 1.1.23 and 1.1.18 When setting dual ign output, it doesn't properly set the h2 values for the 2nd variable in the array .ini file contains an error, and calls out the 3rd variable twice look for h21_dummy h23_dummy h23_dummy should be h21_dummy h22_dummy h23_dummy etc. This error is also present in MegaTune + firmware 1.0.73 release!! Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.