##### ## #### ## #####
## ### ## ## ## ####
_ _ | \ | | | \| | | . ` | | |\ | \_| \_/
# ### ## # # # #
##### ## ##### ## ######
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Small (appr 4 liter) gas engine, '''4 cylinder''', 1500 RPM (some comments on this page are Hungarian) ---- '''Grounds''' * EC36/5 * EC36/21 * EC36/22 * EC36/32 * EC36/26 See MembersPage/PhatBob/UserGuide ---- '''Supply +12V or +13.5V''' (not +24V !!!) * EC36/25 (1-3A fuse, if stepper output not used) ---- '''Sensors''' '''5 EGT''' (order comment: "5 EGT inputs") 4 individual + 1 mixed * K-compensation cable (kompenzációs kábellel bekötni) '''CLT''' Coolant Temperature (hengerfej víz temperature) * EC36/14 (és a GND közé) '''MAT''' Manifold Air Temperature (gázkeverék temperature osztócsoben) * EC36/2 (és a GND közé) '''TPS''' (folytószelep pozíció) * EC36/1 (0-5V analog) * MAP : pneumatic connector (0-300 kPa ?) ---- '''Trigger input''' * EC36/27 Primary trigger, HALL 6-1 (or 6-2) ** configurable rising (felfutó) or falling (lefutó) edge ** after missing tooth, recommended pulse positions: 72 BTDC, 12 BTDC (75-70 and 15-10 fokkal felso holtpont elott) * EC36/13 Secondary trigger: HALL, 1 pulse ** configurable rising (felfutó) or falling (lefutó) edge ** (vezermutengely jelado, a fotengely hianyzo fogatol legalabb 70 fokra) EC36/28: +5V output for HALL sensors ('''max 50mA''' recommended) ---- '''Ignition outputs''' (1,3,4,2 firing order) * EC36/34 (IGN/2) cyl1 * EC36/36 (IGN/3) cyl3 * EC36/24 (IGN/6) cyl4 * EC36/10 (IGN/7) cyl2 4A biztosítékon át a gyújtótrafó másik vége tápfeszre (+12V vagy +24V DC) van kötve ---- '''IAC PWM output''' * Power Throttle Valve (teljesítmény pillangószelep) ** 0-90% (or 10-90% ) ** EC36/pin11 (ign4) 0/5V ('''max: 1.1mA''') ** alternatively: EC18/pin4 (Stepper A) 0/12V ---- '''Mixture valve''' * PWM or 0-5V analog signal (with RC filtering): ** EC36/12 (ign/5 logiclevel). Low current signal, do not load. ('''max: 1.1mA''') ---- '''2nd RS232''' for CRC protected special commands * Modbus RTU 9600-38400,8n1 recommended, configurable up to 115200,8n1 (8e1 also possible, but rarely used) * Modbus address configurable (2 in the examples: ALS_deactivation time=0.2 sec means modbus address=2) Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.