### ## ##### ## ## ##
### ## ## ## ## ####
__ __ \ \/ / \ / / \ /_/\_\
### ## ## ##### ## ## ## ## ######
##### ## ## ## ## ##### ## ##
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: Nissan CA18DET trigger problem. I have a project with a OEM nissan CAS that does not woth with any of the trigger presets. Its the as with the misubishi logo on it. I have run both Sr20 and RB engines with oem disks with the newer firmwares, why is the CA not implemented? Do is have de same disk as one of the others? SR or EVO? We get RPM signal on Both SR 8-2-2-2 and 16-2-4-8 and EVO preset. On 16-2-4-8 we do get spark but it fires 2 times fast after each other then noting.. then 2 more fast, and round it goes. We cant get it to TDC, its about 90 degrees off and the ignition output tabel seems t have no effekt at all. On the EVO precet we get RPM reading, about 180, but no spark at all. Please advice of what the problem might be, what type is the disk? EVO or SR or not implemented at all? ----- Hello Engdahl, Please start with the basics, connect and setup your Nissan trigger as follows: * primary trigger goes to the x cyl number window HALL (in your case 4cyl = 4 window). * secondary trigger goes to the 360 tooth. * verify window sync size, this is done as follows: ** forcing the ecu in safe mode, easiest todo by changing the prohibit low byte from (xx which is last two number of firmware version) to some other number. ** make a triggerlog cranking the engine 8-10 seconds ** your triggerlog will have both primary and secondary pulses logged (sectrig only inside the primtooth window). As an example here is a picture of one i made during some testing: http://vems.hu/dave/nissan_360_16-12-8-4_syncup_good.png ** take notes of the window sizes, Nissan trigger will sync to the longest window; for example if you Nissan trigger windows are 8-2-2-2 than we need to sync to 8sectrig window -> sectrig ignore should be set to 5-6. ** make sure to put your prohibit low byte back to the previous value to revert the safe mode. * after window length verifcation and correct configuration make another triggerlog to verify all is well If you have any further questions are problem starting after that, please make a sharing report containing both triggerlogs (safe mode with prim and sectrig), triggerlog after longest window calibration and a short vemslog of the cranking sequence. I'll review and come back to you with my findings. Best regards, Dave Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.