_ _ ( ) _ ( ) | | ( ) | | | | | | | | | (_/ \_) | `\___x___/'
###### ## ## ## ## ##### ## ####
##### ## ## ## ## ## # ####
_____ |__ / / / / /_ /____|
_ / \ / _ \ / ___ \ /_/ \_\
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: I'm building my own data acquisition system and I want to include Wbo2 logging. I am collecting info on how to control the LSU sensor. As an electronic engineer, I have found a little error in the Wbo2 section. In the Vs amplifier part, the code is Wbo2.nernst_target should be 0x8d. The first stage gain is, based on the schematic, Uout= 5 - ((5-Vs) x 4.6). For our application, we have 5-((5-4.45) x 4.6) = 2.47V => 0x7E and not 0x8D like in the code ?!?!?!?!?!? An other thing I can't understand: How do you calculate the real Ip in the sensor only, whithout knowing the sensor's resistance. A part of the current generated by the OPA is flowing also in the 10k resistor. Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.