## ## ##### ## ## ## ## #####
## ## ###### ###### ## ## ## ##
## ## ##### ## ## ## ## ## ## #####
#### ## ##### ## ## ## ## ### ##
_ | \ /\ | \ / / | (_/ / | _ ( | ( \ \ | / \ \ |_/ \/
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: '''MAP-board 1.0''' Important: the pinout of '''internal sensor''' can be found on GenBoard/Manual/Wiring/ManifoldAbsolutePressure http://shop.x-dsl.hu/catalog/images/MAPdongles_and_bare_s.jpg '''Pin1''' (of the black SSC-male connector) '''is the leftmost''' on the above picture (you can verify the pin numbers printed on the female). The packaged sensor is '''casted with epoxy, very durable, you can step on it''' or melt the external softer black part without damage to the internals. The '''400kPa version''' is recommended for > 130kPa (1.3bar, 18psi) boost. On the 12V, 400kPa version, there are some simple extras onboard, like * regulator (so it can be powered from 12V and there is a 5V output) * thermometer (Temperature output) You can tell the different versions by the number of actually present SSC pins (3/4/5). ---- '''Pinout of the 12V, 400kPa version''' - most popular Note that populated this way, the supply has a wide range, and the '''5V is output, not input. Applying 5V to the 5V output is not supported, it might damage the unit. Use the 5V version if you want to power from 5V''' ||'''SSC pin'''|| '''recommended color'''|| '''signal''' || '''range''' || '''note''' || ||1|| white || MAP output || 0 .. 4.8V || 20..400kPa || ||2|| brown || GND || 0V || || ||3|| red || '''5V out''' || 5V || max 80mA. Useful for HALL, TPS, etc... || ||4|| blue || temp out || 0.5 .. 4.5V || NTC, similar U(T) as CLT || ||5|| grey || '''+12V in''' || 6.3 .. 16V || || ---- '''Pinout of the 5V, 400kPa version''' ||'''SSC pin'''|| '''recommended color'''|| '''signal''' || '''range''' || '''note''' || ||1|| white || MAP output || 0 .. 4.8V || 20..400kPa || ||2|| brown || GND || 0V || || ||3|| red || '''5V in''' || 5V || max 10mA || ||4|| blue || temp out || 0.5 .. 4.5V || NTC, similar U(T) as CLT || The first 3 pin is compatible with the MPX4250AP pinout. ---- '''Pinout of the 5V, 250 kPa version''' ||'''SSC pin'''|| '''recommended color'''|| '''signal''' || '''range''' || '''note''' || ||1|| white || MAP output || 0 .. 4.8V || 20..400kPa || ||2|| brown || GND || 0V || || ||3|| red || '''5V in''' || 5V || max 10mA || Note that there is no temperature output in this version. ---- '''See also''' * GenBoard/Manual/Wiring/ManifoldAbsolutePressure - internal version * GenBoard/Manual/PneumaticTube - generally 6/4 mm tube is used. * GenBoard/Manual * GenBoard/Manual/Config/ManifoldAbsolutePressure * WebShop (see Genboard, sensors) Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.