|\ /| | ) ( | | | | | | | | | | | | | | (___) | (_______)
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: V3.3 was populated with D100, a protecting 18V zener (between injector flyback rail and GND5) that provides some protection if the user forgets flyback connection (but doesn't use injector PWMing). '''However, when PWM-ing (non 100% duty) and powerflyback is applied, if injector-common+ is above 13V''', the 18V zener (with very low ampere rating compared to the powerflyback >20A rating) will clamp to GND5 instead towards injector-common through the 5*diode drop powerflyback. Unfortunately the powerflyback was tested with 12V supply and D100 sneaked attention. Note: assembled controllers sent out after 2006-jan-11 have these removed. drawing: D100 diode marked to remove Customers who ordered assembled controller with powerflyback option and don't want to remove D100 themselves should ask in webshop and we provide a shop on their continent to do so. ---- See GenBoard/Manual/PowerFlyback Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.