_ _ | \ | | | \| | | . ` | | |\ | |_| \_|
## ## #### ## #### ## ##
### ## ## ## #### ## ## ####
____ / __ \ | | | | | | | | | |__| | \____/
IMPORTANT: enter the case-INsensitive alphabetic (no numbers) code AND WRITE SOME SHORT summary of changes (below) if you are saving changes. (not required for previewing changes). Wiki-spamming is not tolerated, will be removed, so it does NOT even show up in history. Spammers go away now. Visit Preferences to set your user name Summary of change: '''WBO2 default Config''' - subpage of GenBoard/Manual/WBSensor <code> wbo2_warmup_ramp=A0 # 0.2 V/sec wbo2, warmup ramp speed [1.51 mV/sec] wbo2_warmup_target=FF # variable dropped a long ago wbo2_abs_limit=E4 # wbo2, heater absolute limit [?] (DA) wbo2_limit_maxt=A0 # wbo2, max time spent at abs_limit [262msec] (50) wbo2_fallback=B0 # wbo2, fallback V after maxt (0xC0 will heat it better than 60, especially when 350C exhaust gas cools the 750C sensor element at idle) wbo2_retry_t=06 # wbo2, retry control after [4sec] wbo2_edgetime_corr=BA # variable dropped in most recent firmwares wbo2_edgetime_min=50 # variable dropped in most recent firmwares wbo2_ri_target=AA #wbo2, target Ri (pulse amplitude) [5V/8192] absolute value: pump+ closest to pump- at startup) wbo2_heater_pid_kp=46 wbo2_heater_pid_ki=10 wbo2_heater_pid_kd=1A wbo2_heater_pid_ilimit=80 wbo2_pump_pid_kp=15 wbo2_pump_pid_ki=4E wbo2_pump_pid_kd=00 wbo2_pump_pid_ilimit=84 wbo2_ri_confidence_scale=80 </code> '''Controller specific values:''' * wbo2_nernstdc_target=86 # controller specific (controller not sensitive to very precise setting), usually 0x86 gives most precise 0.45V between nernst and pump- * wbo2_pump_pw_zero=65 ## controller specific. Look up webshop mail (or calibrate for your controller for minimum pump current * See MembersPage/Sprocket/WideBandRiTarget for historical wbo2_ri_target=96 (decimal 150) value, 160..180 (say 170) since firmware 1.2.0 ---- '''Sensor specific''' - See GenBoard/Manual/Config/WidebandCalibration Calibrate yourself in free air, after replacing the sensor! * wbo2_calibration=40 ** start from lower values and increase as necessary *** starting from way too high calibration value might result in "out of range" values, preventing proper calibration. So do NOT start with a 255 value. 10..64 should be good starting point (lambda and O2 will reading will be incorrect before calibration, as expected... The purpose of calibration is to show correct, verified value) Optional: Add document to category: Wiki formatting: * is Bullet list ** Bullet list subentry ... '''Bold''', ---- is horizontal ruler, <code> preformatted text... </code> See wiki editing HELP for tables and other formatting tips and tricks.