# Trigger settings for, 12+1extrapulse crank 4+extrapulse on cam 4cyl Honda K20A engine without camsync # Primary trigger HALL # Secondary trigger HALL: Exhaust(4+1) needed for cam sync # 3th trigger HALL: intake(4pulses), needed for campos for intake cam # Coils work with logiclevel output 0/5V with stock 510ohm series resistors. trigger_tooth=00 another_trigger_tooth=06 tooth_wheel=0C primary_trigger=0A secondary_trigger=02 ignchmax=03 alternate=03 tooth_wheel_twidth[0]=00 tooth_wheel_twidth[1]=78 toothrel_normal=FF h[1]=00 06 00 06 00 00 00 00 config11=30 strig_validation=08 secignore=FF max_prim_per_sec_count=2