# Reduction temperature control from analog 2 input # Used with Egt amplifier (240C/V converter) # 650C-> 2,71V # 700C-> 2,91V # analog target(named boost target) = 120 # pid kp= 14 # input_val = 150 -> DC= 5.1% # input_val = 90 -> DC= 15.7% #Curve must set 2.71->150 -> bins have to set 2,813 : 120 ; 2,500: 208 #Curve must set 2.91->90 -> bins have to set 2,813 : 120 ; 3,125: 31 pwm0=00 pwm4=00 analin2_curve[0]=D0 analin2_curve[1]=D0 analin2_curve[2]=D0 analin2_curve[3]=D0 analin2_curve[4]=D0 analin2_curve[5]=D0 analin2_curve[6]=D0 analin2_curve[7]=D0 analin2_curve[8]=D0 analin2_curve[9]=78 analin2_curve[A]=1F analin2_curve[B]=1F analin2_curve[C]=1F analin2_curve[D]=1F analin2_curve[E]=1F analin2_curve[F]=1F analin2_curve[G]=1F analin2_cal=20 analin2_offset=00 analin2_mode=03 analin_limiter=3F pwm_out4_control_kp=0D pwm_out4_control_ki=00 pwm_out4_control_kd=00 pwm_out4_control_ilimit=00 pwm_out4_control_mode=F5 pwm_out4_control_fixrefdc=19 pwm_out4_control_fixtarget=3C pwm_out4_control_mindc=00 pwm_out4_control_maxdc=FF